INVERTER / CHARGER User Manual *with built-in 60amp MPPT SCCPIP-MS 1-5KVA (800W-4KW)

Strany 2 - Table Of Contents

8 5. Make sure the wires are securely connected. PV Connection CAUTION: Before connecting to PV modules, please install separately a DC circuit b

Strany 3 - SAFETY INSTRUCTIONS

9 PV Module Selection: When selecting proper PV modules, please be sure to consider below parameters: 1. Open circuit Voltage (Voc) of PV modules

Strany 4 - INTRODUCTION

10 Communication Connection Please use supplied communication cable to connect to inverter and PC. Insert bundled CD into a computer and follow on-s

Strany 5 - Product Overview

11 OPERATION Power ON/OFF Once the unit has been properly installed and the batteries are connected well, simply press On/Off switch (located on th

Strany 6 - INSTALLATION

12 LCD Display Icons Icon Function description Input Source Information Indicates the AC input. Indicates the PV input Indicate input voltage, i

Strany 7 - Battery Connection

13 In battery mode, it will present battery capacity. Load Percentage Battery Voltage LCD Display Load >50% < 1.717V/cell 1.717V/cell ~ 1.

Strany 8 - CAUTION!!

14 LCD Setting After pressing and holding ENTER button for 3 seconds, the unit will enter setting mode. Press “UP” or “DOWN” button to select setting

Strany 9 - AC Input/Output Connection

15 10A (Not available for 2-3KVA 24V Plus) 20A 30A 40A 50A 60A (default) Available options in 4K/5K model 70A 80A 9

Strany 10 - PV Connection

16 07 Auto restart when over temperature occurs Restart disable (default) Restart enable 08 Output voltage (only available for 120Vac models) 1

Strany 11 - Final Assembly

17 12 Setting voltage point back to utility source when selecting “SBU priority” or “Solar first” in program 01. Available options in 24V models: 22

Strany 12 - Dry Contact Signal

Table Of Contents ABOUT THIS MANUAL ...

Strany 13 - OPERATION

18 26.5V 27V (default) 27.5V 28V 28.5V 29V Available options in 48V models: Battery fully charged 48V 49V 50V 51V 52V 53V 54V (default)

Strany 14 - LCD Display Icons

19 Solar and Utility (Only available for 4KVA/5KVA model) Solar energy and utility will charge battery at the same time. Only Solar Solar e

Strany 15

20 If self-defined is selected in program 5, this program can be set up. Setting range is from 24.0V to 29.2V for 24V model and 48.0V to 58.4V for 48

Strany 16 - LCD Setting

21 Display Setting The LCD display information will be switched in turns by pressing “UP” or “DOWN” key. The selectable information i

Strany 17

22 Battery voltage/ DC discharging current Battery voltage=25.5V, discharging current=1A Output frequency Output frequency=50Hz Load percentage Loa

Strany 18

23 Load in Watt When load is lower than 1kW, load in W will present xxxW like below chart. When load is larger than 1kW (≧1KW), load in W w

Strany 19

24 Operating Mode Description Operation mode Description LCD display Standby mode / Power saving mode Note: *Standby mode: The inverter is not tu

Strany 20

25 Battery Mode The unit will provide output power from battery and PV power. Power from battery and PV energy. Power from battery only. Fault

Strany 21

26 Warning Indicator Warning Code Warning Event Audible Alarm Icon flashing 01 Fan is locked when inverter is on. Beep three times every second

Strany 22

27 SPECIFICATIONS Table 1 Line Mode Specifications INVERTER MODEL 1KVA 24V 2KVA 24V 3KVA 24V 1KVA 48V 3KVA 48V 2KVA 24V Plus 3KVA 24V Plus 2KVA 48V P

Strany 23 - Display Setting

1 ABOUT THIS MANUAL Purpose This manual describes the assembly, installation, operation and troubleshooting of this unit. Please read this manual

Strany 24

28 Table 2 Inverter Mode Specifications INVERTER MODEL 1KVA 24V 2KVA 24V 3KVA 24V 2KVA 24V Plus 3KVA 24V Plus 1KVA 48V 3KVA 48V 2KVA 48V Plus 3KVA 48

Strany 25

29 Table 3 Charge Mode Specifications Utility Charging Mode INVERTER MODEL 1KVA 24V 2KVA 24V Plus 120Vac 2KVA 24V 3KVA 24V 2KVA 24V Plus 3KVA 24V Plu

Strany 26 - Operating Mode Description

30 Joint Utility and Solar Charging (Only available for 4KVA and 5KVA model) Max Charging Current 120Amp Default Charging Current 60Amp Table 4 G

Strany 27 - Fault Reference Code

31 TROUBLE SHOOTING Problem LCD/LED/Buzzer Explanation / Possible cause What to do Unit shuts down automatically during startup process. LCD/LEDs

Strany 28 - Warning Indicator

32 Appendix: Approximate Back-up Time Table Model Load (VA) Backup Time @24Vdc 100Ah (min) Backup Time @24Vdc 200Ah (min) 1KVA 200 766 1610 400

Strany 29 - SPECIFICATIONS

33 Model Load (VA) Backup Time @ 48Vdc 100Ah (min) Backup Time @ 48Vdc 200Ah (min) 2KVA 200 1581 3161 400 751 1581 600 491 1054

Strany 30

2 INTRODUCTION This is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer uninterru

Strany 31

3 Product Overview 1-3KVA model NOTE: For parallel model installation and operation, please check separate parallel installatio

Strany 32

4 INSTALLATION Unpacking and Inspection Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should

Strany 33 - TROUBLE SHOOTING

5 Install the unit by screwing three screws. 1-3KVA 24V, 1KVA/3KVA 48V model 2-3KVA 24V/48V Plus, 4-5KVA 48V model Batte

Strany 34

6 Please follow below steps to implement battery connection: 1. Assemble battery ring terminal based on recommended battery cable and terminal size.

Strany 35

7 AC Input/Output Connection CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between inverte